Introduction of Helium Leak Detector:
If you are working with systems that require leak-tightness, you need a reliable method to detect and locate small leaks. Helium leak detection is a widely used technique that can help you achieve that. Helium leak detector works by introducing helium gas into a sealed container or system. Once helium is introduced into the system, a helium mass spectrometer is used to detect the presence of helium in the surrounding area. The mass spectrometer is a highly sensitive instrument that can detect the smallest amounts of helium, even in the presence of other gases.
Technical Parameters of Flow Rate Airghtness Helium Leak Detector:
Airtightness Helium Mass Spectrometer Leak Detector Use in Pressurized Systems |
||||
---|---|---|---|---|
Product Name |
Helium Leak Detector |
|||
Flow Sensor |
Display Precision |
The value can be set to 0 to 4 decimal places |
||
Sensor Range |
LC103 (V5) |
30mL/min~1000mL/min (optional) |
||
|
LC101 (V6) |
15mL/min~1000mL /min (optional) |
||
Sensor Error |
±3%F.S.(optional) |
|
|
|
Direct Pressure |
Display Precision |
The value can be set to 0 to 4 decimal places |
||
Recommended Test Pressure Range |
LC103 (V5) |
Mechanical Pressure Regulating |
10~600kPa (Optional) |
|
LC101(V6) |
Mechanical Pressure Regulating |
10~600kPa (Optional |
||
Sensor Error |
±0.1%FS. |
|
||
Display Unit |
Test Pressure |
kPa,Mpa,kg/cm2,psi,mbar.bar, Torr,mmH,O,mmHg |
||
Leakage |
mL/s,mL/min,L/min,Lh,m3/h,Pa/min,g/h,SCCM |
|||
Parameter Program Number |
64 groups(1~64) |
|||
Test Beat Setting |
0~3600 seconds |
|||
Power Supply |
AC220V±10%, 50Hz |
|||
Test Pressure Source |
Clean, Dry, Adequate flow, no less than 500KPa and 100KPa above the test pressure source |
|||
Overall Diamensions |
Standard V5 |
330mm*222mm*448mm |
||
Standard V6 |
321mm*205mm*560mm |
|||
Weight |
About 15kg |
Applications of Airtightness Leak Detector:
Helium leak detector is also used in the medical sector for various applications. Some of the most common medical applications of helium leak detection include:
Leak testing of medical gas systems, including oxygen, nitrogen, and carbon dioxide systems
Testing of vacuum systems used in medical equipment, such as MRI machines
Leak testing of anesthesia machines
Leak testing of sterilization equipment
Helium leak detector is preferred in medical applications because it is non-toxic, non-reactive, and does not leave any residue. This ensures the safety and purity of medical gases and equipment, which is critical for patient safety.
Support and Services of Helium Leak Detector:
Installation Assistance: Guidance through the setup process to ensure your leak detector is installed correctly and functioning optimally right from the start.
Operational Training: Comprehensive training sessions for operators to become proficient in using the device, understanding its features, and interpreting results accurately.
Software Updates: Regular updates to the device's software to ensure you have access to the latest features, improvements, and security enhancements.
Repair Services: In the event of a malfunction, we offer repair services to restore your device to its full functionality as quickly as possible.