Place of Origin:
China
Brand Name:
Wayeal
Certification:
CE
Model Number:
LC3200
Introduction of High Performance Liquid Chromatography Instrument
The HPLC high performance liquid chromatography Intrument LC3200 offers exceptional performance and reliability in liquid chromatography. Its robust design and reliable performance make it suitable for a variety of applications. It is easy to use and its intuitive user interface enables users to quickly set up and run experiments. With its high performance and reliability, the high performance liquid chromatography Intrument is the perfect choice for any laboratory.
Technical Data of High Performance Liquid Chromatography Instrument:
Manufacturer: | Wayeal |
Product Name: | Liquid Chromatography Instrument |
Working Power Supply | 220V, 50Hz |
Ambient Temperature | 10~40°C |
Relative Humidity | 20~85% |
Qualitative Repeatability | ≤0.2% |
Quantitative Repeatability | ≤0.4% |
High Pressure Constant Flow Pump | |
Flow Rate Range | 0.001~10.000mL/min |
Setting Step | 0.001mL/min |
Pressure Range | 0~42MPa |
Pressure Pulsation | 0.1MPa |
Flow Rate Set Error | ±0.2% |
Flow Rate Stability | RSD≤0.06% |
Gradient Error | ±1% |
Column Oven | |
Temperature Control Range | 4~85°C |
Temperature Stability | ±0.02°C |
Temperature Setting Resolution | 0.1°C |
Autosampler | |
Injection Volume Repeatability | <0.5%RSD |
Linearity | >0.9999 |
Cross Contamination | <0.002% |
Injection Volume Accuracy Error | ±1% |
Sample Positions | 120 |
Injection Volume | 1~100μL |
UV Detector | |
Baseline Noise | ≤2.0*10-6Au |
Baseline Drift | ≤1*10-5Au/h |
Mini Detection Concentration | ≤3.0*10-9g/mL (naphthalene/methanol) |
Spectral Range | 188~900nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥103 |
DA Detector | |
Baseline Noise | ≤4*10-5Au |
Baseline Drift | ≤3*10-5Au/h |
Mini Detection Concentration | ≤2*10-8g/mL |
Spectral Range | 190~800nm |
Wavelength Error | ≤±0.1nm |
Wavelength Repeatability | ≤±0.1nm |
Linearity Range | ≥ 104 |
ELS Detector | |
Baseline Noise | ≤ 0.0037mV |
Baseline Drift | ≤ 0.0026mV/30min |
Evaporation Gas Flow Range | (0 ~ 3) SLM |
Atomization Temperature Range | Room temperature ~ 90℃ |
Evaporation Temperature Range | Room temperature~110℃ |
Detection Chamber Temperature Range | Room temperature~60℃ |
Input Air Pressure | (4 ~ 7) bar |
FL Detector | |
Baseline Noise | ≤ 5×10-6 FU |
Baseline Drift | ≤ 2 × 10-5 FU/30min |
Spectral Range | (200 ~ 650) nm |
Wavelength Error | ± 0.1 nm |
Linearity Range | ≥ 104 |
RI Detector | |
Detection Range | 0.25 ~ 512 μRIU |
Linearity Range | ≥ 600 μRIU |
Response Time | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 sec; |
Cell Volume | 8μL |
Applications of High Performance Liquid Chromatogaphy Instrument:
Wayeal LC3200 high performance liquid chromatograph (HPLC) machine is a reliable and powerful liquid chromatography instrument that offers excellent performance and speed.
In the pharmaceutical industry, HPLC high performance liquid chromatography is used in research and development, manufacturing quality control, and impurity and degradation analysis to ensure that drugs are free of unintended or harmful ingredients.
Clinical laboratories apply HPLC high performance liquid chromatography to analyze complex biological fluids such as blood, plasma and serum to assist in the development of targeted precision drugs.
HPLC (high performance liquid chromatography) is used in the food and beverage industry to detect pesticide residues and to verify the purity and authenticity of ingredients, and HPLC analysis helps ensure that food and beverages are unadulterated and free of harmful toxins and carcinogens.
Send your inquiry directly to us