Place of Origin:
Anhui, China
Brand Name:
Wayeal
Certification:
ISO, CE
Model Number:
IC6200
Wayeal IC6200 Column Oven Equipped Ion Chromatography Intrument Applied in Clinical Studies
Introduction of Ion Chromatography Instrument
Ion chromatography (IC) systems separate charged particles from a liquid and measure their concentration. IC systems can analyze particles such as anions, cations, organic salts, and proteins. They are used in environmental, manufacturing, food, pharmaceutical, and chemical industries. Key things to consider when purchasing an IC system include: number of samples, range of sample volume, whether eluent is generated by the system, flow and pressure of the column, and ease and functionality of the chromatography data system software.
Features of Ion Chromatography Instrument
1. Intergrated apperance design, high brightness LCD full touch GUI controller
2. High degree of automation "One Key Rinse" and "One Key Maintenance" automatic maintenance function.
3. Higher intergration: Support optional parts upgrade to 2D system and multi-detector combination.
4. Full PEEK pump and electric injection valve.
5. Powerful and convenient chromatpgraphy workstation
6. High precision temperatur-controlled conductivity detector.
Parameters of Ion Chromatography Instrument
Wayeal IC6220 Column Oven Equipped Liquid Ion Chromatography Applied in Clinical Studies |
|
System Parameter |
|
Qualitative Repeatability |
≤0.5% |
Quantitative Repeatability |
≤1.0% |
Pump System |
|
Flow Rate |
(0.001~10.000) mL/min |
Pump Head Pressure Resistance |
(0 ~ 35) MPa |
Flow Rate Setting Inaccuracy |
<0.1% |
Flow Stability |
<0.1% |
Pressure Display Accuracy |
0.01Mpa |
Pressure Pulsation |
<0.5% |
Conductivity Detector |
|
Baseline Noise |
≤0.1%FS |
Baseline Drift |
≤0.5%FS |
Minimum Detectable Concentration (Cl) |
≤ 0.0002μg/mL |
Minimum Detection Concentration (Li) |
≤ 0.0001μg/mL |
Conductivity Cell Volume |
≤ 0.6μL |
Conductivity Detection Range |
0-15000μS/cm |
Detector Resolution |
0.00238nS/cm |
Conductivity Cell Temperature Setting Error |
±0.01°C |
Resolution of Conductivity Cell Temperature Display |
0.001°C |
Suppressor |
|
Constant Current Source Range |
0-500mA in 0.1mA increments |
Column Oven |
|
Temperature Range |
Room temperature +5°C~85°C |
Control Temperature Stability |
≤ 0.1°C |
Autosampler |
|
Number of Sample Vials |
≥ 120 (1.5ml standard sample bottle) |
Repeatability |
Full loop injection < 0.3% RSD, Partial injection < 0.5% RSD, Non-destructive injection < 1 % RSD (injection volume > 5μL) |
Syringe Size |
Standard: 500μL; optional; 250μL, 1000μL, 2500μL |
Loop Size |
Standard: 100μL; optional: 20μL, 50μL, 200μL |
Linearity |
>0.999 |
Cross-contamination |
<0.01% |
Eluent Generator |
|
Flow Rate Range |
0.001 to 3.000mL/min |
Eluent Concentration Range |
KOH, MSA-0.1 to 100mM |
Concentration Accuracy |
0.1mM |
Original Concentration of Electrolyte |
25% KOH/MSA |
Volume of Electrolyte |
1000mL |
Maximum Working Pressure |
21MPa (3000psi) |
Gradient Accuracy |
1.5% |
Industry Application
Liquid ion concentrations i.e.,drinking water,ground water,factory effluent
Adhesion ion concentrations (extracting adhering ions with pure water)
Ion concentrations in gas (collecting ions in gas with collection liquid)
Anion : F-, Cl-, Br-, BrO3- , NO3- , NO2- , SO42- , PO43-
Cation : Li+,Na+,NH4+,K+,Mg2+,Ca2+ can be quantified.
Send your inquiry directly to us