logo
Send Message
Home > products > Atomic Absorption Spectrophotometer >
Double Beam AAS Atomic Absorption Spectrophotometer Wayeal

Double Beam AAS Atomic Absorption Spectrophotometer Wayeal

Double Beam AAS Spectroscopy

Dual Beam Atomic Absorption Spectrophotometer

Double Beam Double Beam Atomic Absorption Spectrophotometer AAS

Place of Origin:

Anhui, China

Brand Name:

Wayeal

Certification:

ISO

Model Number:

AA2300

Contact Us
Request A Quote
Product Details
Product Name:
Atomic Absorption Spectrophotometer AA2300
Injection Bits:
108
Heating Rate:
3000°C/s
Injection Volume:
1-200μL
Zero Drift(Abs/30min):
±0.002/30min
Spectral Bandwidth:
0.1, 0.2, 0.4, 1.0, And 2.0nm
Highlight:

Double Beam AAS Spectroscopy

,

Dual Beam Atomic Absorption Spectrophotometer

,

Double Beam Double Beam Atomic Absorption Spectrophotometer AAS

Payment & Shipping Terms
Minimum Order Quantity
1
Price
Negotiation
Packaging Details
Wooden Case
Delivery Time
30 days
Supply Ability
30 Pieces Per Month
Product Description

Hollow Cathode Lamp and Nebulizer Double Beam AAS Atomic Absorption Spectrophotometer
 
Introduction of Atomic Absorption Spectrophotometer
Atomic absorption spectroscopy (AAS) is based upon the principle that free atoms in the ground state can absorb light of a certain wavelength. These very specific wavelengths give the technique excellent specificity and detection limits in the AAS analysis. 

 
Parameters of Atomic Absorption Spectrophotometer AA2300

Hollow Cathode Lamp and Nebulizer Double Beam AAS Atomic Absorption Spectrophotometer

Wavelength range(nm) 185-900nm
Wavelength indication error(nm) ±0.15nm
Wavelength repeatability(nm) ≤0.05 nm
Spectral Bandwidth 0.1, 0.2, 0.4, 1.0, and 2.0nm
Zero Drift ±0.002/30min
Instantaneous noise(Abs) ≤0.002 Abs
Flame Atomizer  
Detection limit Cu: ≤0.002μg/mL
Repeatability RSD≤0.25%
Graphite Furnace Atomizer  
Detection limit(Graphite Furnance: Cd pg) ≤0.3pg
Repeatability RSD≤1.5 %
Heating temperature room temperature -3000°C or so
Heating rate 3000°C/s
Autosampler  
Injection bits 108
Linear >0.999
Injection volume 1-200μL
Injection volume repeatability ≤0. 1%
Result repeatability ≤1.5%
Background correction Deuterium lamp
Lamp position 8

 
Features of Atomic Absorption Spectrophotometer AA2300

1.Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
2.Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
3.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
4.Long-life and anti-corrosive atomization system:The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.


Applications of Atomic Absorption Spectrophotometer
Atomic absorption spectroscopy is an extremely important analytical method in the field of analytical chemistry. It has been widely used in metallurgy, food, agriculture, chemical industry, environmental protection and materials science. At present, atomic absorption spectrophotometer has become one of the tools for metal element analysis and trace analysis.

Double Beam AAS Atomic Absorption Spectrophotometer Wayeal 0
Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 2Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 3Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 4Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 5Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 6Double Beam Graphite AAS Atomic Absorption Spectrometer For Metal Analysis 7

Send your inquiry directly to us

Privacy Policy China Good Quality Helium Leak Detector Supplier. Copyright © 2022-2025 Anhui Wanyi Science and Technology Co., Ltd. . All Rights Reserved.